Page 33 - WTS Catalog 2025
P. 33
aPower 2
AC-coupled battery
Store solar generated power while the sun is shining. Use the
stored energy when needed to lower electric bills. Run heavy
loads such as air conditioners and water heaters as usual even
during grid outages. Provide homeowner peace of mind by fully
charging before severe weather events.
The system is off-grid ready, designed to operate
independently from the main power grid to deliver reliable
energy in any situation.
10 kW continuous / 15 kW peak for 10s
8 kW charge power
15 kWh AC1 per unit, up to 225 kWh (15 units) per aGate
60 MWh warranty throughput
PERFORMANCE SPECIFICATIONS MECHANICAL SPECIFICATIONS
SKU APR-10K15V2-US 45.2 in × 29.5 in × 11.8 in
Model Number aPower 2 Dimensions (H × W × D) (1149 mm × 750 mm × 300 mm)
Nameplate /Certification aPower X-20 Weight, aPower 2 Complete 357 lb. (162 kg)
CEC Listing Name aPower Xyyy Weight, without Cover 335 lb. (152 kg)
Battery Chemistry Lithium Iron Phosphate (LFP) Weight, Cover 22 lb. (10 kg)
Usable System Energy 15 kWh AC1 per unit, up to 15 units per aGate Mounting Wall or floor mount
Aggregate Throughput 60 MWh Cooling Natural air-cooled design
Real Power (charge) 8 kW continuous
Nominal Output Power (AC) 11.8 in
2.5 kW 5 kW 6.7 kW 8.4 kW 10 kW2 (300 mm)
Maximum Apparent Power 29.5 in 29.5 in
2.9 kVA5.8 kVA 7.7 kVA9.6 kVA 11.5 kVA (750 mm) (750 mm)
Maximum Continuous Current 12 A 24 A 32 A 40 A 48 A
Nominal AC Voltage 11.8 in
120 / 240 V, 120 / 208 V (single phase), 60 Hz (300 mm)
Coupling
AC-coupled
Phase
2 W+N+PE
Round Trip Efficiency
90%1 45.2 in 45.2 in
Maximum Short-Circuit Current Rating (1149 mm) (1149 mm)
10 kA
Load Start Capability
Up to a 5-ton air conditioner
Self-Consumption
Work Modes Time of Use
Emergency Backup
Noise Emission 30 dB(A) Typical / 45 dB(A) Maximum
Flood Resistance Up to 29” from the aPower 2 base
User Interface FranklinWH App
Warranty 15 years3
COMPLIANCE INFORMATION
UL 9540, UL 9540A, UL 1973, UL 1741, UL1741 SB, UL
Certifications 1741 PCS, UL 60730-1, IEEE 1547, IEEE 1547.1, UN 38.3,
CSA C22.2 No. 107.1
Seismic AC 156, OSHPD, IEEE 693-2005 (high)
California Proposition 65
Environmental RoHS Directive 2011 / EU
Emissions FCC Part 15 Class B, ICES 003
1. At beginning of life, 3 kW charge/discharge power, 77 °F (25 °C).
2. Refer to the installation manual and commissioning guide for proper wire and OCPD sizes.
3. For more details, please refer to the FranklinWH System Limited Warranty for End Users available in the
Documentation Center on the FranklinWH website.
W W W . F R A N K L I N W H . C O M